新闻详情
dcdc module power supply ripple test method!
The index of the dcdc module is a very important parameter. In order to determine the quality of the power supply,dcdc module power supplyThe output ripple is measured. However, the ripple value measured by many people is often hundreds of mV, or even hundreds of mV, which is far larger than the larger ripple value provided in the device manual. This is mainly caused by incorrect measurement methods.
Oscilloscope parameter requirements: support bandwidth limit function: general oscilloscopes support 20MHz bandwidth limit, such as: SDS1102CM.
Probe requirements: In order to make the ground wire as short as possible, try to use the original test short needle of the probe. The copper wire in the class wire is of moderate strength (still a little soft, please recommend if there is a better one). Other candidates are solder wire and cutters. Choose the 1X non-attenuation gear. Generally, when the passive probe is in the 1X gear, its bandwidth is limited to 6MHz/10MHz bandwidth, so that the front end can effectively filter out the interference of high-frequency noise and reduce the impact of ripple measurement.
dcdc module power supply ripple measurement method:
1. Limit the bandwidth of the oscilloscope to 20MHz (most of the low-end oscilloscope gears are limited to 20MHz, and high-end products have a 200MHz bandwidth limit option), the purpose is to avoid the high frequency noise of the digital circuit from affecting the ripple measurement, and try to ensure the accuracy of the measurement ;
2. Set the coupling mode to AC coupling, which is convenient for measurement (use a smaller gear to carefully observe the ripple, and do not care about the DC level);
3. Ensure that the probe grounding is as short as possible (the main reason for the measurement ripple of hundreds of mV is that the grounding wire is too long), try to use the original short test needle that comes with the probe. If there is no short test needle, you can remove the ground wire and shell of the probe to expose the probe crust, and wind the self-made ground wire around the probe crust to ensure that the length of the ground wire is less than 1cm;
4. The oscilloscope ground is suspended, and only the probe ground is shared with the reference point of the test signal. Do not share the ground with the test equipment by other means. This will introduce a lot of ground noise to the ripple measurement. For example: when the oscilloscope and other instruments share the power strip, the switches of other instruments may cause noise interference to the test through the ground wire.
Related News
- Is the power supply module customized or universal?
- Common general technical indicators of military power supplies
- How to choose a special power supply manufacturer
- The development trend of power module customization industry
- Industrial control power supply manufacturers talk about the characteristics of industrial control power supply
- The purpose of acdc power supply module
- Advantages of dcdc power module
- The scope of military power applications tends to be life-oriented
- The progress of military power
- About the high reliability of military power supply
- Requirements for custom-made power supply modules
- The power industry's requirements for the selection of dcdc power supply modules
- Industrial control power supply manufacturers analyze the working process of industrial power supply
- Power module customization analysis of the difference between switching power supply and module power supply
- Causes of high temperature failure of dcdc power supply modules
- Design considerations for dcdc power supply modules
- Special power supply manufacturers tell you how to suppress electromagnetic interference
- The advantages of power modules are more conducive to the development of military power modules
- Factors to consider when choosing a dcdc module power supply
- Special power supply manufacturers analyze the method of power module heat dissipation